EEC 346 Rotating Electrical Machines Tutorial 2024
About this paper
Tutorial sheet on synchronous generators for Rotary Electrical Machines (EEC 346): induced electromotive force, voltage regulation by the synchronous impedance, magnetomotive force and zero power factor (Potier) methods, and performance of a 50 MVA generator from its open-circuit characteristic.
Opens this paper in the app on your phone.
University of Buea
College of Technology - COT
Rotating Electrical Machines
Tutorial · Second Semester · Level 300
From this paper
- 1.
What will be the rms value of emf induced per phase in 3-phase, 6-pole, star-connected alternator having a stator with 90 slots and 8 conductors per slot? The flux per pole is 4 × 10−2 Wb and it runs at a speed of 1000 rpm. Assume full-pitched coils and sinusoidal flux distribution.
- 4.
A three-phase, star-connected, 10 kVA, 230 V alternator has an armature resistance of 0.5 Ω per phase and a synchronous reactance of 1.2 Ω per phase. Calculate the percent voltage regulation at full load at power factors of (a) 0.8 lagging, (b) 0.8 leading, (c) Determine the power factor such that the voltage regulation becomes zero on full load.